11. E. Holding the hub securely, insert the first vacutainer tube following proper order of draw into the large end of the hub penetrating the stopper. Avoid drawing blood from a hematoma. Individually packaged 70% isopropyl alcohol wipes. 13. 4 0 obj 0000010686 00000 n Screw it tightly using a clockwise motion. CHnX&J44 Disposable, safety needle (21G, 22G, or 21, 23, 25G butterfly needles) B. i$o.-N %0 $e5eC6X} &f V)Z|{as@l G9@(+3`'I'N =I*+L'n. /BitsPerComponent 8 The single-use device reduces the risk of transfer-related injuries, while maintaining the specimen integrity required for accurate results. The Importance of Early Learning for Growing Kids. tubing and no luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. xref BD Vacutainer SST Venous Blood Collection Tube Serum Tube Clot Activator / Separator Gel Additive 16 X 100 mm 8.5 mL Red / Gray Mottled Conventional Closure Plastic Tube A Blood test is prescribed in most of the blood-related disorders, metabolic disorders and in various infections as well as for the Regular health Check-ups.
/Domain[0 1] PRESS sample blood tube(s) on to vacutainer needle. 6. %PDF-1.5 % 7.1.4.5 Refer to BD Vacutainer Venous Blood Collection Tube Guide for complete listing and description: The vacuum tubes are designed to draw a predetermined volume of blood. Vacutainer tube holder 5. <>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/StructParents 0>> 6. and syringe, avoid drawing the plunger back too forcefully. Related Products: Edta Tube. The Supervisor should be called to assess the patient. <]/Prev 425510/XRefStm 1663>> BD and the BD Logo are trademarks of Becton, Dickinson and Company. 0000013853 00000 n B. 14. Gloves are to be worn during all phlebotomies, and changed between patient collections. transfer device to fill vacutainer tubes, allow the vacuum to pull the blood. Notify your supervisor or patients physician if unsuccessful. /Filter[/FlateDecode] << [5][6][7], The term order of draw refers to the sequence in which tubes should be filled. This usually takes 15-30 minutes. stream /Filter[/FlateDecode] trailer This decreases the complexity of steps for mononuclear cell separation, thereby minimizing variability from sample processing. <>/OutputIntents[<>] /Metadata 580 0 R>> Screw it tightly using a clockwise motion. Vacutainer Plasma Preparation Tubes (PPT) BD. tubing and pre-attached holder in a fully sterilized package, offering an integrated device that may simplify the phlebotomy procedure. BD's collection of literature on industry and on our offerings gives you information you can use to continue striving for excellence. D. Holding the needle in line with the vein, use a quick, small thrust to penetrate the skin and enter the vein in one smooth motion. endobj The Blog is basically devoted to the Paramedical personnels who risk their life to save the life of other peoples. 1. Other products you might be interested in, BD Vacutainer push button blood collection set, BD Vacutainer Safety-Lok blood collection set, BD Vacutainer Eclipse blood collection needle, Surgical Instruments and Sterilization Container products. Overview The BD Vacutainer Safety-Lok blood collection set is simple, easy to use and safety engineered. /Length 13388 [2] Vacutainer is a registered trademark of Becton Dickinson, which manufactures and sells the tubes today.[3][4]. %%EOF Now ensure the patient what is to be done. Mk endobj 2. The safety mechanism can be activated immediately after the blood draw and helps protect against needlestick injury. Gloves are to be discarded in the appropriate container immediately after the phlebotomy procedure. Cap Colour - White. Required fields are marked *. Trace elements, heavy metals, most drug levels, This page was last edited on 29 January 2023, at 20:59. /Size[255] 1 I am a Medical Lab Tech, a Web Developer and Bibliophiliac. %PDF-1.4 <>stream (adsbygoogle = window.adsbygoogle || []).push({});
. Tubes must be positively identified after filling with a firmly attached patient label. 9. BD Vacutainer Safety-Lok Blood Collection Set with 12 in. 10. 0000009959 00000 n A range of Vacutainer tubes containing blood, Learn how and when to remove this template message, "Vacutainer and Their Use in Blood Sampling", "A golden age of clinical chemistry: 19481960", "Blood collection: routine venipuncture and specimen handling", "Effects of standard anticoagulants and storage procedures on plasma glucose values in seals", "BD Vacutainer Venous Blood Collection Tube Guide", "An Appraisal of the "Vacutainer" System for Blood Collection", https://en.wikipedia.org/w/index.php?title=Vacutainer&oldid=1136329583. UF Health Pathology Laboratories Nontuberculosis Mycobacteria Laboratory, This page uses Google Analytics (Google Privacy Policy). endobj 21 G x .75 in. Observe universal (standard) safety precautions. /Length 581 15. endobj SST PST EDT A S . 0000009632 00000 n 8. BD Vacutainer PPT Plasma Preparation Tubes. 3. BD Vacutainer Safety-Lok Blood Collection Set with 7 in. All other trademarks are the property of their respective owners. /Range[0 1 0 1 0 1 0 1] Clean the puncture site by making a smooth circular pass over the site with the 70%alcohol pad, moving in an outward spiral from the zone of penetration. Features and Benefits Glass and plastic options How to Give Yourself a Spa-Like Facial Massage and Lymphatic Drainage? << How to Optimise Your Diet to Help With Fertility? 1. 1 0 obj The Veterinary Surgeon may cleanse the skin of the horse from where the blood sample is to 12. /FunctionType 0 4. These tubes are used primarily for chemistry tests. <> 0000007374 00000 n 13x75 mm 3.0 mL BD Vacutainer plastic P700 plasma tube. Continue exchanging the tubes until the required no. Blood samples should Do not attempt a venipuncture more than twice. %PDF-1.5 The needle which pierces the tubes can carry additives from one tube into the next, so the sequence is standardized so that any cross-contamination of additives will not affect laboratory results.[7]. We support our products with extensive clinical expertise and educational materials to help you achieve the best possible results. {Fe./l3*k%5!xY}?y;+yPy1P3wF stream 11. Blood Collection Tubes. BD and the BD Logo are trademarks of Becton, Dickinson and Company. (5 ways), Signs That Your Period is Coming Tomorrow: 6 Vital Signals, Care and Maintenance of Laboratory Equipment. It is available with a preattached holder for added convenience and to help meet the Occupational Health and Safety Administration's (OSHA) single-use standards. stream POLICY: By establishing a procedure for the correct collection of blood by venipuncture many pre-analytical errors and patient management complications can be avoided. bssohtBPh:Qm~{(+w-YXCJ{o[v\/;f.:rH]6X[9mW2cXuzD8nI[pF_]/ObX/}oR:9gGv:tayw]Qqc"h~X[1Y=8UmU6LeS8H\qOWG}CLBKJ]%fNI5[lF F0zhy*B yquZXy[ES6"8km Ad7i#bdd! If commercially available tubes are to be used, the researcher should use the red topped tubes. Gray Top (plasma): Contains sodium fluoride/potassium oxalate. v1Znrch6j]6f~NcD!~-+ @ejLcPe&[c Paper label. and amount of blood is obtained for analysis. BD supports the healthcare industry with market-leading products and services that aim to improve care while lowering costs. Observe all applicable isolation procedures. 0000011799 00000 n a BD Vacutainer Safety-Lok Blood Collection Set. 1 0 obj 9. stream Green Top (plasma): With and without gel, contains lithium heparin. Place a gauze pad over the puncture site and remove the needle. PROCEDURE 1. 2023 BD. into the tubes; do not use the plunger on the syringe to force . endobj Refer to the specific test in the online directory for handling and storage requirements. Hold the unit & needle steady with your left hand. 0000000016 00000 n 0000011261 00000 n Blood Collection Process: Venipuncture Venipuncture Procedure PDF ROUTINE VENIPUNCTURE GUIDELINES MATERIALS 1. 0000005296 00000 n BD Vacutainer SST Venous Blood Collection Tube Serum Tube Clot Activator / Separator Gel Additive 16 X 100 mm 8.5 mL Red / Gray Mottled Conventional Closure Plastic Tube Vacutainer tubes may contain additives designed to stabilize and preserve the specimen prior to analytical testing. Never leave the tourniquet on for over 1 minute. Holding the needle in line with the vein, use a quick, small thrust to penetrate the skin and vein in one motion. Apply the tourniquet 3-4 inches above the collection site. A sales representive will get in touch with you shortly. To prevent excess vacuuming on a syringe, consider the use of vacutainer blood collection tubes, which create a vacuum seal inside the tube to facilitate the draw of a pre-determined . In the case of an accidental needlestick, immediately wash the area with an antibacterial soap, express blood from the wound, and contact your supervisor. The BD Vacutainer blood transfer device was designed with healthcare workers safety in mind. 13x75 mm 2.4 mL BD Vacutainer glass plasma ESR tube. [14] The Vacutainer was preceded by other vacuum-based phlebotomy technology such as the Keidel vacuum. gr @5c3Ok=3. A sales representive will get in touch with you shortly. 0000001256 00000 n BD's collection of literature on industry and on our offerings gives you information you can use to continue striving for excellence. Now Assemble the vacutainer holder & needle by inserting short end of the vacutainer needle which is covered with the rubber coating into the threaded end of the holder. This aid in the prevention of bruising and edema formation. tubing and luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. This procedure establishes criteria for the proper collection of blood specimens. We host and take part in events that excel in advancing the world of health. BD promotes clinical excellence by providing various resources on best practices, clinical innovations and industry trends in healthcare. The BD Vacutainer CPT Cell Preparation Tube with Sodium Citrate is an evacuated blood collection tube system containing 0.1 M sodium citrate anticoagulant and blood separation media composed of a thixotropic polyester gel and a FICOLL Hypaque solution. Push the tube all the way into the holder with your thumb until the needle completely punctures the rubber stopper of the vacutainer tube. Perform activation and staining or fixation of platelets within 10 minutes of blood collection. Assemble the necessary equipment appropriate to the patients physical characteristics. DO NOT SHAKE OR MIX VIGOROUSLY. 25 G x .75 in. >> (adsbygoogle = window.adsbygoogle || []).push({});
, Needle gauge For Adults: 20-22 G & For Children: 23-24 G, Check out the blood collection by Capillary puncture. The BD Vacutainer blood transfer device is designed with healthcare workers' safety in mind. Venipuncture procedure when evacuated tube system (Vacutainer) is used /Length 22 8. These tubes can also be used sometimes for the collection of urine samples. The use of a needle to transfer venous blood from a syringe to a blood collection tube or blood culture bottle is both a dangerous procedure and an OSHA-prohibited practice. <>>> These are available from Becton Dickinson (BD). 0000034815 00000 n % HANGING DROP PREPARATION TO EXAMINE THE MOTILITY OF MICROORGANISM / BACTERIA, PREPARATION OF PHOSPHATE BUFFER SOLUTION IN LABORATORY, 6 Things to Consider Before Building Your Clinic, Exploring The Benefits of Microdosing Magic Mushrooms: A Comprehensive Guide. Patient safety is the ultimate . 0000182132 00000 n Tubes are available with a safety-engineered stopper, with a variety of labeling options and draw volumes. Each tube is topped with a color-coded plastic or rubber cap. 155 0 obj These tubes are used for coagulation tests and need to be completely filled to ensure the proper ratio of blood to anticoagulant. The plastic tube version, known as Vacutainer PLUS, was developed at B-D in the early 1990s by E. Vogler, D. Montgomery and G. Harper amongst others of the Surface Science Group as US patents 5344611, 5326535, 5320812, 5257633 and 5246666.[15]. Syringes 4. 0000020236 00000 n 4. All other items used for the procedure must be disposed of according to proper biohazardous waste disposal policy. <> Ask the patient to make the fist. BD is the inventor of BD Vacutainer blood collection tubes as well as the worldwide leader in blood tubes. /FunctionType 0 The re-use of vacutainer blood tube holders is strictly prohibited by OSHA and BVHS. 5. This order of draw should be followed whenever multiple tubes are drawn during a single venipuncture. 5 0 obj BD and the BD Logo are trademarks of Becton, Dickinson and Company. When the required amount of the blood obtained, carefully pull the tube downwards, off the tube end of the needle and out of the holder. 10. >> <> endobj For Research Use Only. Release the tourniquet. A vacutainer blood collection tube is a sterile glass or plastic test tube with a colored rubber stopper creating a vacuum seal inside of the tube, facilitating the drawing of a predetermined volume of liquid. 23 G x .75 in. Tick off the collected samples on the Blood Worksheet (Attachment 1) /BitsPerSample 8 5. 6. A Vacutainer blood collection tube is a sterile glass or plastic tube with a closure that is evacuated to create a vacuum inside the tube facilitating the draw of a predetermined volume of liquid. Blood specimen collection collection accessories Browse all specimen collection products BD Vacutainer gel tubes FAQs General SST and PST questions SST-specific tube questions Contact Sales Contact Support Please note, not all products, services or features of products and services may be available in your local area. 0000218054 00000 n BD VacutainerSafety-Lok blood collection set. 1 0 obj endobj Pull the skin tight with your thumb or index finger just below the puncture site. endobj The Central Blood Analysis Laboratory (CBAL) will be responsible for special blood collection and handling protocols as well as training and QC monitoring at the Clinical Centers. Carefully Remove the needle from the syringe and gently expelthe blood into the appropriate vial or container. 3. All surfaces are cleaned daily with bleach. Antiseptic. It is not recommended that blood be drawn from the feet .The Providers permission is required to draw from this site. n. % Overview The use of a needle to transfer venous blood from a syringe to a blood collection tube or blood culture bottle is both a dangerous procedure and an OSHA-prohibited practice. When a tube is inserted into the holder, its rubber cap is punctured by this inner needle and the vacuum in the tube pulls blood through the needle and into the tube. Tubes often include additives that mix with the blood when collected, and the color of each tube's plastic cap indicates which additives it contains. 0000015023 00000 n [1, 2, 3] Veins have a three-layered wall composed of an internal endothelium surrounded by a thin layer of muscle fibers, which in turn is surrounded by a layer of connective tissue.Identification of the optimal site for venous access (see Technical . 0000182441 00000 n 2 0 obj Use another tube as vacuum may have been lost. But there should not be any air present in the syringe at the time of blood collection. 1. 0000013645 00000 n Using the wrong tube may make the blood sample unusable for the intended purpose. [/Separation/BD#20Gold/DeviceCMYK 2 0 R] 0000010912 00000 n 2 0 obj 7. Implant Dentistry: A permanent solution to tooth loss, Top Tips to Build Self-confidence in Your Dyslexic Child, How To Use Hair Shampoo: Step-By-Step Guide for Best Results, The Importance Of Concussion Education For Medical Professionals, 10 Facts About Artificial Tooth Replacement That Will Make You Smile. /TR/Identity Gently invert tubes containing an additive 5-8 times. 3 0 obj A sales representive will get in touch with you shortly. Other products you might be interested in, BD Vacutainer Stretch latex-free tourniquet, Surgical Instruments and Sterilization Container products. Vacutainer tubes may contain additives designed to stabilize and preserve the specimen prior to analytical testing. 4 0 obj >> << All rights reserved. 0000099961 00000 n endobj 1. Subscribe To Our Newsletter To Get All The Updates Right in Your Inbox, BLOOD COLLECTION BY VENIPUNCTURE SYRINGE AND VACUTAINER METHOD, REQUIREMENTS FOR THE BLOOD COLLECTION BY SYRINGE METHOD, PROCEDURE OF THE BLOOD COLLECTION BY SYRINGE METHOD, REQUIREMENTS FOR THE BLOOD COLLECTION BY VACUTAINER METHOD, PROCEDURE OF BLOOD COLLECTION BY VACUTAINER METHOD. Release tourniquet and collect blood into a labeled ACD VACUTAINER tube. 1 0 obj (6 J. 5. Firstly ensure that the patient should be in the comfortable position. Specimens should not be obtained from the arm on the same side as a mastectomy. Transfer Device 6. 5.4 Collect blood into three (3) 8ml CPT tubes per sample using the standard technique for BD Vacutainer Evacuated Blood Collection Tubes (see Venipuncture Technique & Sample Collection section and Prevention of Backflow section). /Height 64 Now decide the amount of blood required and select the appropriate vials or containers according to the tests to be done. All rights reserved. Place the needle bevel up in the line with the vein, decrease the angle of the needle until it is almost parallel to the skin surface direct the needle towards the vein and pierce the skin and vein wall at approximately at15-30 angle. Volume - 3ml. BD Vacutainer Safety-Lok Blood Collection Set with 7 in. When bleeding stops, apply a fresh bandage, gauze or tape. With the right hand, Grasp the vacutainer unit (Vacutainer holder+needle) and remove the translucent plastic cover from the needle. 202 0 obj The additives may include anticoagulants (EDTA, sodium citrate, heparin) or a gel with density between those of blood cells and blood plasma. 0000009374 00000 n Activate the safety device and properly dispose of the vacutainer holder with needle attached into a sharps container. Transfer Device 6. X mmms?mmnM Vacutainer tubes may contain additional substances that preserve blood for processing in a medical laboratory. This procedure is one example of a variety of methods that can be used to activate platelets. )jVdZV46 Allow each tube to fill up with the adequate amount of blood required for the lab tests ordered. Main Line Health Laboratories provides the following standard procedure for venous blood collection. For the Separation of Mononuclear Cells from Whole Blood Sterile Interior 8 mL Draw Capacity (16 x 125 mm Tube Size) VDP40393(02) 362753 2020-05 INTENDED USE The BD Vacutainer CPT Cell Preparation Tube with Sodium HeparinN is an evacuated Tube intended for the collection of whole blood and the separation of mononuclear cells. 3 0 obj f4.H7dyqAxBXaww;lf6[M\7IW1 #?Ogm "84$ Do not touch the puncture site after cleaning. ESG (Environmental, Social, and Governance), Policies, Guidelines and Statements Center, Our live chat is available between the hours of 8.30am - 5.00pm EST, Monday - Friday, BD Original Equipment Manufacturing (OEM), Patient Care Support Across the Continuum. 6%L)v`"V$gdHI"@lBm venipuncture site is dry. The BD EST tubes are plastic tubes and have no additive in them. Call Customer Service 800.964.5227 Product description Ordering information 21 G x .75 in. <> 0000001663 00000 n Withdraw the needle slowly, and tell the patient to place a cotton swab over the wound until the blood ceases. %PDF-1.3 endobj BD's trade name for the blood handling tubes is Vacutainer. After collection of the whole blood, allow the blood to clot by leaving it undisturbed at room temperature. 3 0 obj Your email address will not be published. If using a blood. Now, remove the Tourniquet, ask the patient to open the fist and place the cotton swab over the needle and wound. BD Vacutainer plastic tubes offer a safe method of blood collection and reduce the potential for tube breakage and specimen spillage, thereby reducing the potential for exposure to bloodborne pathogens. In most cases, another puncture in a site below the first site is advised. BD offers training resources to help improve your clinical practices as part of our goal of advancing the world of health. Blood collection procedures should be approved by the institutional ethics committee (AWERB, IACUC or equivalent) and detailed in the approved study protocol. How to buy Reach out to our team for ordering information. If no patient labels are available, manually label the tubes with the required information. /Width 63 The filled tube is then removed and another can be inserted and filled the same way. Bd Vacutainer System Tube Guide Pdf . Disposable, single use needle holder C. Evacuated blood collection tubes D. Tourniquet (non-latex), disposable single use Used primarily for hematology and blood bank testing. stream tubing and no luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. A lab coat or gown must be worn during blood collection procedures. 21 G x .75 in. B06 Whole blood (for DNA extraction) 3 Vacutainer EDTA 3 ml 1.1 Blood collection Ensure that the vacutainer tubes are appropriately coded according to own routine procedures. If the child is old enough, collect blood as in an adult. x][s~wgRE\-gNi0${je"6 A`Y'3 FC>Ww>nW\]:}]m/(?}rWV0^_? The BD Vacutainer one-use holder is compatible with the entire BD Vacutainer blood collection system: the BD Vacutainer Eclipse blood collection needle, the BD Vacutainer Safety-Lok blood collection set, BD Vacutainer push button blood collection sets and BD Vacutainer multiple sample luer adapters. BD Vacutainer Safety-Lok Blood Collection Set with 12 in. Save my name, email, and website in this browser for the next time I comment. 7. BD Vacutainer CPT is a fully-closed system for separation of mononuclear cells from whole blood, where cell separation is carried out in the primary blood collection tube. Single use, disposable, latex-free tourniquets. 0000018520 00000 n The label must include the patient first and last names, DOB,, collection date and time and collectors initials. Usually drawn first for minimal risk of contamination. |IRHcqR/_|A)PIi# _K:jB|-$-0d8(Qg/dfK@ff.h0 7)^!2$2Gd$Id"L4X}uV@M#2hhQ1454WJf=cMA95x`#u1D26i The larger median cubital, basilic and cephalic veins are most frequently used, but other may be necessary and will become more prominent if the patient closes his fist tightly. >> Additionally, some tubes contain additives that preserve certain components of or substances within the blood, such as glucose. 0000002627 00000 n Secure patient to Papoose apparatus for stabilization if child is unable to sit upright on their own. The following order of draw is the approved order as established by CLSI. The color of cap is used to identify these additives. 0000014235 00000 n 0000011440 00000 n We host and take part in events that excel in advancing the world of health. tubing and luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. % K2 EDTA 5.4 mg and proprietary DPP-IV inhibitor that enables preservation of GLP 1. 23 G x .75 in. 21g or less 3. 2. With your left hand, slightlypull back the piston till the required amount of blood is obtained into the syringe. 0000010186 00000 n This information must match the requisition. 5. hb```f``a`c`9 B@16%;00h9|9eqGW,"v5Ir'VJYTJ-YbggElZ9@I:Gx-Mj] 1 AEGGG The BD Vacutainer blood transfer device was designed with healthcare workers' safety in mind. This blood will be used for staining. tubing and pre-attached holder in a fully sterilized package, offering an integrated device that may simplify the phlebotomy procedure. Up]Inm$.q[ Q>>Ocm1$'C3+BH&zn7bgRpq$MO^! Make sure the. BD's collection of literature on industry and on our offerings gives you information you can use to continue striving for excellence. tubing and no luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. Procedure 1. Refer to the eLab 155 48 At no time may phlebotomists perform venipuncture on an artery. BD Vacutainer Safety-Lok Blood Collection Set with 12 in. Used for chemistry and reference tests. X [endstream 0000002445 00000 n tubing and luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. Your email address will not be published. With the left hand, hold the patients arm so that the skin over the vein gets tightened and more prominent. 0 0000181762 00000 n x][s~W$}7bDYSJH] Reassure the patient that the minimum amount of blood required for testing will be drawn. 10. tubing and luer adapter features a forward-shielding safety mechanism that helps protect against needlestick injury. MBi(. The Vacutainer Blood Collection Tubes, both plastic and glass, are engineered to reduce specimen spillage.The Safety-Lok Blood Collection Sets and the Eclipse Blood Collection Needles feature a patented . Place a gauze pad over the puncture site and quickly remove the needle. Probing is not recommended. Study Guide and Procedure Checklist Manual Package: An Applied Learning Approach, 13th Edition . 2 0 obj 13. Lay the arm of the patient on the table. Vacutainer technology was developed in 1947 by Joseph Kleiner,[2] and is currently marketed by Becton Dickinson (B-D). The laboratory will also be responsible for performing assays and reporting results. The meanings of the various colors are standardized across manufacturers. /Range[0 1 0 1 0 1 0 1] <>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> 9. Now Assemble the vacutainer holder & needle by inserting short end of the vacutainer needle which is covered with the rubber coating into the threaded end of the holder. Safety Needles, 22g or less 2. Extensive scarring or healed burn areas should be avoided. 2. Ll Instruct the patient to apply the pressure over the wound until the blood ceases. G. When blood flow stops, remove the tube by holding the hub securely and pulling the tube off the needle. XUwpYfU!%JeU{ B $@ a$44q hhzgvv7v^{kLfEsK=*D~so1(c5Z0k0P$6!_ Chg$XFUl5 Arthroscopy Trays; Circumcision Trays; Ophthalmic Trays; Shoulder Trays; Stockinettes; Surgical Drapes #labtechniciancourse #laboratory #bloodcollection #labtech #bloodsample #bloodbank #collection #trending #viral #viralvideo #video #metropolis #hospital Phlebotomy is a technique in which a needle is temporarily inserted into a vein to provide venous access for venous blood sampling. BD promotes clinical excellence by providing various resources on best practices, clinical innovations and industry trends in healthcare. All rights reserved. 0000015594 00000 n We support our products with extensive clinical expertise and educational materials to help you achieve the best possible results. BD is the inventor of BD Vacutainer blood collection tubes as well as the worldwide leader in blood tubes. Vacutainers have the advantage of being prepared with additives, allowing easy multi-tube draws, and having a lower chance of hemolysis. Vacutainer tube holder. *E)\,SDh,M2YdC*6TjM,SU[f+6To>;PcvVB:u{f/>h?p`B9&sMG(14h1>'rbNdZOi;#gnVKy9r!b:/tY"WmU\Kur#6fzo#woW}?`yCrhG1q<>O`yOSsjg1/Kr)S/vE^jf\2Y7)of-y+sowGnE,~(f#(KYD>iVvw=6-'l4?cu~o;v}?=?/5cO?dendstream Now Instruct the patient to relax and unclench the fist and release the tourniquet after the required amount of blood is obtained as per the tests to be done and prepare to withdraw the needle. A. 0000001840 00000 n <>>> 0000036227 00000 n Ask the patient to apply pressure to the gauze for at least 2 minutes. Yellow Top (plasma and cells): Contains ACD solution A or B. Blood Collection Tubes. $Q7 wcHoz.=}/ot}divr/>~qwk|bvszz}3}66-?{W? Ensure that the collection tube is completely pushed onto the back of the needle in the hub. 0000003048 00000 n Ask the patient to apply pressure for at least 2 minutes. <>/ExtGState<>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> Seal-Tight Disposable Air/Water Syringe Tip; Sterile Procedure Trays . 5.5 After collection, store tube upright at room temperature until centrifugation. 25 G x .75 in. 7. "kB#i]#}= -XIYFIO^qpr;aR endobj Dispose of the syringe and needle as a unit into an appropriate sharps container. 2. If using a needle. }J]UV\e|}*>O\,qTC\q\/'rYR.>v 6EoO^jUqU],?B`|9N]7K!A*K i6]IRwLvHH&UnbQ4 ,oluQzO#L_n(^}Qa$}T-o?%RrcSI+VBIQhUD*n5g1k.Tkmm/u|gAz-+)m[dmNjKU 2. Select the appropriate vein for venipuncture. My greatest hobby is to teach and motivate other peoples to do whatever they wanna do in life. This latex-free, single-use device Compare this item 10. The tourniquet will be applied 3-4 inches above the selected puncture site and will not . If hands are not visibly contaminated a commercial foaming hand wash product may be used before and after each patient collection. V(5/^O[$thW)Y".`JET(5:rSG H;_=6V3b-C+364,--N`T S`"Mv"T4JU )IMK_V ?RS\SV & >b~5dU 3v:*[;"-*Kb>I1 OI(lQZa@UJI%G\XvTNcJl]XR~zb-Xu h Jhic4 If anticoagulant is used, gently shake the vials for proper mixing of the blood with the anticoagulant. ZAJezAqPfI1-4o0]wh1_ea.wWnn;,7\[j@.4cj'DU)ai0A9v}p sh5TK@h %XZE#eCKnL- Most commonly used to draw the blood samples directly from the vein. Some test specimens require special handling for accurate results. BD 362725 EST Plastic Tube 3ml with Pearlescent White Hemogard Closure 10 [Pack of 1000] Excl. Guide to using the BD Vacutainer Blood Collection Set NHS Fife 1.93K subscribers Subscribe 18K views 3 years ago Health & Safety Manager, Craig Webster, gives advice on the safe use of the BD.